photo

Ankerbouten

FM en UL Logo



Installation

installation

installation

Loads and performance data     M 8 M 10 M 12 M 16
      cracked concrete
Mean ultimate loads, tenstion C25/30
Num
[kN] 10,5 14,7 28,0 35,1
Mean ultimatel loads, shear C25/30
Vum
[kN] 19,0 26,9 40,5 73,3
Approved loads, tension C20/25 appr.N [kN] 2,4 4,3 7,6 11,9
  C25/30 appr.N [kN] 2,6 4,7 8,3 13,1
  C30/37 appr.N [kN] 2,9 5,2 9,3 14,5
  C40/50 appr.N [kN] 3,4 6,0 10,8 16,8
  C50/60 appr.N [kN] 3,7 6,6 11,8 18,5
      non-cracked concrete
Approved loads, tension C20/25 appr.N [kN] 5,7 7,6 11,9 16,7
  C25/30 appr.N [kN] 6,3 8,4 13,0 18,3
  C30/37 appr.N [kN] 7,0 9,3 14,5 20,3
  C40/50 appr.N [kN] 7,5 10,7 16,8 23,5
  C50/60 appr.N [kN] 7,5 11,8 18,4 25,8
      cracked / non-cracked concrete
Approved loads, shear C20/25 appr.V [kN] 8,6 12,6 17,1 26,9/34,3
  >C25/30
appr.V
[kN] 8,6 12,6 17,1 29,6/34,3
Approved bending moments appr.M [Nm] 13,1 26,9 46,9 119,4
             
Spacing and edge distance            
Effective anchorage depth Hef [mm] 46 60 70 85
Characteristic spacing Scr,N [mm] 138 180 210 255
Characteristic edge distance Ccr,N [mm] 69 90 105 127,5
             
Minimum spacing and edge distance for standard thickness of concrete member
      cracked concret
Minimum spacing / for edge distance c smin / c [mm] 40 /0 45 / 70 60 / 100 60 / 100
Minimum edge distance / for spacing s cmin / s [mm] 40 / 80 45 / 90 60 / 140 60 / 180
      non-cracked concrete
Minimum spacing / for edge distance c smin / c [mm] 40 / 80 45 / 70 60 / 120 65 / 120
Minimum edge distance / for spacing s cmin / s [mm] 50 / 100 50 / 100 75 / 150 80 / 150
Standard thickness of concrete slab Hstd [mm] 100 120 140 170
             
Minimum spacing and edge distance for minimum thickness of concrete member
      cracked concrete
Minimum spacing / for edge distance c smin / c [mm] 40 / 70 45 / 90 60 / 100 70 / 160
Minimum edge distance / for spacing s cmin / s [mm] 40 / 80 50 / 115 60 / 140 80 / 180
      non-cracked concrete
Minimum spacing / for edge distance c smin / c [mm] 40 / 80 60 / 140 60 / 120 80 / 180
Minimum edge distance / for spacing s cmin / s [mm] 50 / 100 90 / 140 75 / 150 90 / 200
Minimum thickness of concrete slab hmin [mm] 80 100 120 140
             
Installation parameter            
Drill hole diameter do [mm] 8 10 12 16
Diameter of clearance hole in the fixture df [mm] 9 12 14 18
Depth of drill hole h1 [mm] 60 75 90 110
Installation torque Tinst [Nm] 20 25 45 90
Installation torque SW [mm] 13 17 19 24